Safe Levels of RF Radiation by
Different Telecommunication Industries

FCC (Federal Communications Commission) - United States

  • Occupational Exposure Limit: 5 mW/cm² (5000 µW/cm²) averaged over any 6-minute period.

  • General Public Exposure Limit: 1 mW/cm² (1000 µW/cm²) averaged over any 30-minute period.

  • Source: FCC Guidelines for Human Exposure to RF Electromagnetic Fields

ICNIRP
(International Commission on Non-Ionizing Radiation Protection)

  • Occupational Exposure Limit: 10 W/m² (1000 µW/cm²) for frequencies between 10 MHz and 300GHz.

  • General Public Exposure Limit: 2 W/m² (200 µW/cm²) for frequencies between 10 MHz and 300 GHz.

  • Source: ICNIRP Guidelines

IEEE (Institute of Electrical and Electronics Engineers)

  • Occupational Exposure Limit: 10 mW/cm² (10000 µW/cm²) for frequencies between 3 kHz and 300GHz.

  • General Public Exposure Limit: 1 mW/cm² (1000 µW/cm²) for frequencies between 3 kHz and 300 GHz.

  • Source :IEEE C95.1-2019

ARPANSA

(Australian Radiation Protection and Nuclear Safety Agency)

  • Occupational Exposure Limit : 10 W/m² (1000 µW/cm²) for frequencies between 100 kHz and 300 GHz.

  • General Public Exposure Limit: 2 W/m² (200 µW/cm²) for frequencies between 100 kHz and 300 GHz.

  • Source :ARPANSA Radiation Protection Standard

Health Canada

  • Occupational Exposure Limit : 10 W/m² (1000 µW/cm²) for frequencies between 3kHz and 300 GHz.

  • General Public Exposure Limit: 2 W/m² (200 µW/cm²) for frequencies between 3 kHz and 300 GHz..

  • Source : Health Canada Safety Code 6

All Combined

Regulatory Body

Occupational Exposure Limit

General Public Exposure Limit

Source

FCC (USA)

5 mW/cm²
(5000 µW/cm²)


50,000,000
(µW/m²)

averaged over any 6-minute period

1 mW/cm²
(1000 µW/cm²)


10,000,000

(µW/m²)

averaged over any 30-minute period.


FCC Guidelines

ICNIRP (International)

10 W/m²
(1000 µW/cm²)

10,000,000

(µW/m²)

2 W/m²
(200 µW/cm²)

2,000,000

(µW/m²)

ICNIRP Guidelines

IEEE (USA)

10 mW/cm²
(10000 µW/cm²)

100,000,000

(µW/m²)

1 mW/cm²
(1000 µW/cm²)

10,000,000

(µW/m²)

IEEE C95.1-2019

ARPANSA (Australia)

10 W/m²
(1000 µW/cm²)

10,000,000

(µW/m²)

2 W/m²
(200 µW/cm²)

2,000,000

(µW/m²)

ARPANSA Standard

Health Canada

10 W/m²
(1000 µW/cm²)

10,000,000

(µW/m²)

2 W/m²
(200 µW/cm²)

2,000,000

(µW/m²)

Health Canada Safety Code 6


**These limits are set to protect against the known thermal effects of RF exposure. However, they may not account for potential non-thermal biological effects that are suggested by some scientific studies. The BioInitiative Report and the Building Biology Institute advocate for much lower exposure limits to protect against these non-thermal effects.

To convert from µW/cm² to µW/m², you need to understand the relationship between square centimeters and square meters.

1 square meter (m²) = 10,000 square centimeters (cm²).

So,to convert µW/cm² to µW/m²: µW/m²=µW/cm²×10,000\text{µW/m²} = \text{µW/cm²} \times 10,000µW/m²=µW/cm²×10,000